10A 16A 20A 25A 32A 40A 2P 4P RCBO

10A 16A 20A 25A 32A 40A 2P 4P RCBO
Detay yo:
● Nimewo mòd: EZ40
● IEC/EN61009-1
● Wide ranje evalyasyon aktyèl soti nan 6A a 40A
● Nimewo poto: 1P+N, 3P+N (N Pol sou bò gòch)
● Rated kouran sansiblite I△n: 10, 30, 100, 300mA
● Kapasite Rated Kout Awondisman: 6kA
● Tripping koub: B ak C
● Kalite vwayaj: (1) Fòt tè: Elektwo-mayetik; (2) Surcharge, Kout Awondisman: Thermo-mayetik
● Rated vòltaj: 1P + N: 230/240V ~, 3P + N: 400/415V ~
● Kalite tripping: AC, A, ASi, F
Voye rechèch
Dekri teren
Voye rechèch
Deskripsyon Product

 

● Nimewo mòd: EZ40

● IEC/EN61009-1

● Wide ranje evalyasyon aktyèl soti nan 6A a 40A

● Nimewo poto: 1P+N, 3P+N (N Pol sou bò gòch)

● Rated kouran sansiblite I△n: 10, 30, 100, 300mA

● Kapasite Rated Kout Awondisman: 6kA

● Tripping koub: B ak C

●Type nan vwayaj: (1) Fòt tè: Elektwo-mayetik; (2) Surcharge, Kout Awondisman: Thermo-mayetik

● Rated vòltaj: 1P + N: 230/240V ~, 3P + N: 400/415V ~

● Kalite tripping: AC, A, ASi, F

 

image001

 

Entwodiksyon

 

WEAG EZ40 seri 10A 16A 20A 25A 32A 40A 2P 4P RCBO (Residual Current Operated Circuit Breakers) se aparèy elektrik ki fèt pou bay pwoteksyon kont defo elektrik, patikilyèman defo tè ak kouran flit. RCBO sa yo konbine fonksyon yon disjoncteurs ak yon aparèy kouran rezidyèl (RCD) nan yon sèl inite.

 

Disjoncteur pwoteksyon "Liy Faz + net + flit" espesyalman fèt pou itilize nan sikui rezidansyèl sèl-faz opere nan 50Hz oswa 60Hz, ak yon ranje vòltaj rated 230-400V. Li fèt pou pwoteje kont flit, surcharge elektrik sivil, ak sikui kout.

 

WEAG EZ40 seri 10A 16A 20A 25A 32A 40A 2P 4P RCBO ofri plizyè avantaj, ki gen ladan yon ti gwosè, gwo kapasite kraze, ak kapasite nan ansanm koupe zewo-liy la ak liy ap viv la. Sa vle di ke nan evènman an nan yon fay, tou de liy yo net ak vivan yo dekonekte. Anplis de sa, RCBO a bay pwoteksyon flit menm nan ka fil elektrik ranvèse nan liy lan ap viv la.

 

Konfòmite ak estanda IEC61009-1 asire ke pwodwi a satisfè kondisyon sekirite ak pèfòmans entènasyonalman rekonèt. Teknoloji avanse ki enkòpore nan RCBO yo plis amelyore fyab yo ak efikasite.

 

An rezime, seri WEAG EZ40 10A 16A 20A 25A 32A 40A 2P 4P RCBO yo se aparèy kontra enfòmèl ant ki konbine disjoncteurs ak fonksyon rezidyèl aparèy aktyèl la. Yo fèt pou pwoteje kont defo tè, kouran flit, surcharge elektrik, ak sikui kout nan sikui rezidansyèl sèl-faz. RCBO sa yo konfòme yo ak estanda IEC61009-1 yo epi enkòpore teknoloji entènasyonal avanse pou bay pwoteksyon serye ak efikas.

 

Avantaj

 

WEAG EZ40 disjoncteurs kouran rezidyèl opere:

● Pa gen bezwen pou ekipman pou pouvwa oksilyè, simonte enpèfeksyon yo nan rezistans entèferans pòv ak sansiblite nan fluctuations vòltaj nan pwodwi elektwonik, osi byen ke enkapasite a bay pwoteksyon lè fil net la dekonekte, elaji sijè ki abòde lan nan pwoteksyon aktyèl rezidyèl.

● Segondè rated kout-sikwi kraze kapasite, jiska 6kA.

● Kontwòl dinamik nan kous tès la, ki pa fasil domaje nan rezistans tès la.

● Mekanis pwoteksyon enstantane tripping la adopte yon konsepsyon reglabl, asire presizyon ak fyab nan tripping enstantane pwodwi a.

● Se mekanis nan fonksyone ki fèt kòm yon mekanis depo enèji, kote kontak dinamik la kouran pandan operasyon an fèmen, pèmèt fèmen an rapid nan kontak la dinamik ak amelyore lavi sèvis li yo ak kapasite kraze nan pwodwi a.

 

Aplikasyon

 

WEAG EZ40 rezidyèl aktyèl opere disjoncteurs aplikasyon prensipal yo bay pwoteksyon kont danje chòk elektrik ak anpeche dife elektrik ki te koze pa defo tè oswa kouran flit. Yo souvan itilize nan enstalasyon elektrik rezidansyèl, komèsyal ak endistriyèl. Men kèk aplikasyon espesifik kote WEAG EZ40 RCBO yo souvan itilize:

● Bilding rezidansyèl yo: WEAG EZ40 RCBO yo lajman itilize nan kay ak apatman konplèks pou bay pwoteksyon pou sikui elektrik. Yo anjeneral enstale nan tablo distribisyon oswa inite konsomatè yo pwoteje sikui endividyèl, tankou ekleraj, priz kouran, ak aparèy kwizin.

● Bilding Komèsyal: Nan anviwònman komèsyal yo, WEAG EZ40 RCBO yo enstale pou pwoteje sikui ki alimante divès ekipman ak sistèm elektrik. Yo souvan itilize nan biwo, magazen an detay, otèl, ak lòt komèsyal yo.

● Enstalasyon Endistriyèl: WEAG EZ40 RCBO nan anviwònman endistriyèl kote yo itilize ekipman elektrik ak machin. Yo enstale pou pwoteje sikui ki alimante machin lou, motè, ak lòt ekipman endistriyèl.

● Enstalasyon deyò: WEAG EZ40 RCBO ki fèt pou itilize deyò yo itilize nan aplikasyon tankou ekleraj deyò, priz elektrik jaden, ak pisin. RCBO sa yo fèt pou kenbe tèt ak kondisyon deyò, ki gen ladan imidite ak pousyè.

● Ekipman espesyalize: WEAG EZ40 RCBO yo itilize tou pou bay pwoteksyon pou kalite espesifik ekipman oswa aplikasyon ki mande plis mezi sekirite. Egzanp yo enkli ekipman medikal, sant done òdinatè, ekipman laboratwa, ak aparèy elektwonik sansib.

 

Done teknik

 

Estanda

IEC/EN61009-1

Pwoteksyon

Fòt tè, Surkouran, Kout Awondisman

Kalite vwayaj

Fay tè: elektwo-mayetik

Surcharge, Kout Awondisman: Thermo-mayetik

Kalite pwoteksyon (fuit elektrik)

AC, A

No de poto

2P (1P + N), 4P (3P + N), N Pol sou bò gòch

Kouran nominal (nan)

6, 10, 16, 25, 32, 40A

Kapasite Rated Kout Awondisman

6000A

Aktyèl lage tèmik

(1.13-1.45) Nan

Kouran lage mayetik

B tip: 3-5 Nan; Kalite C: 5-10 Nan

Klas limitasyon enèji

3

Kouran sansiblite nominale (I△n)

10, 30, 100, 300mA

Kapasite rezidyèl fè ak kraze (I△m)

500A (nan mwens pase oswa egal a 50A)

Rated vòltaj Ue

1P+N: 230/240V~, 3P+N: 400/415V~

Vòltaj izolasyon nominal (Ui)

500V

Rated frekans

50/60Hz

Kout-sikwi aktyèl lnc=l△c

6kA

Rated enpilsyon kenbe tèt ak vòltaj (1.5/50) Uimp

4000V

Rated aktyèl rezidyèl ki pa opere

0.5I△n

 

Lavi elektrik

2, 000 Sik

Lavi mekanik

4, 000 Sik

Klas pwoteksyon

Enstalasyon dirèk

Nan bwat distribisyon

IP20

IP40

Tanperati anbyen

-25 degre a +40 degre

Tanperati depo

-25 degre a +60 degre

Gwosè fil elektrik

Fil kwiv/difisil

Tèminal kòd / Hoop

1-25mm2

1-16mm2

Kalite koneksyon tèminal

Kab/Pin-type busbar/Fork-type busbar

Max. koupl pi sere

2.5Nm

Enstalasyon

Montaje sou tren DIN 35mm

Koneksyon

Soti nan tèt ak anba

Detay anbalaj

1+N

3+N

120Pcs/CTN

60Pcs/CTN

 

Kesyon ak Repons

 

K: Ki sa ki se yon EZ40 RCBO?

A: EZ40 RCBO, oswa Residual Current Operated Circuit Breaker, se yon aparèy elektrik ki konbine fonksyon yon disjoncteurs ak yon aparèy kouran rezidyèl (RCD) nan yon sèl inite. Li bay pwoteksyon kont defo elektrik, patikilyèman defo tè oswa kouran flit.

K: Ki jan EZ40 RCBO travay?

A: EZ40 RCBO kontwole aktyèl la ap koule tankou dlo nan yon kous. Si li detekte yon move balans ant aktyèl la ap koule tankou dlo nan faz la ak kondiktè net, ki endike yon fay tè oswa aktyèl flit, li byen vit dekonekte kous la pou anpeche chòk elektrik oswa domaj nan ekipman yo.

K: Ki avantaj ki genyen nan itilize EZ40 RCBO?

A: EZ40 RCBO yo ofri plizyè avantaj, tankou:
● Pwoteksyon konbine: Yo bay tou de disjoncteurs ak pwoteksyon aktyèl rezidyèl nan yon sèl aparèy.
● Sekirite amelyore: Yo byen vit dekonekte kous la nan ka ta gen defo tè oswa kouran flit, diminye risk pou yo chòk elektrik.
● Fleksibilite: Yo ka enstale nan divès sistèm elektrik ak konfigirasyon.
● Gwosè kontra enfòmèl ant: Yo gen yon anprint ki pi piti konpare ak disjoncteurs separe ak RCD.
● Tripping selektif: Yo ka selektivman trip, sa ki pèmèt sikui espesifik yo dwe izole san yo pa afekte rès la nan enstalasyon an.

K: Ki kote EZ40 RCBO yo souvan itilize?

A: EZ40 RCBO yo souvan itilize nan aplikasyon rezidansyèl, komèsyal ak endistriyèl. Yo souvan travay nan tablo distribisyon elektrik, pwoteje sikui tankou ekleraj, priz kouran, ak aparèy yo.

K: Ki jan ou chwazi EZ40 RCBO pou yon aplikasyon espesifik?

A: Lè w ap chwazi EZ40 RCBO, konsidere faktè tankou aktyèl aktyèl ak vòltaj sikwi a, ki kalite chaj yo pwoteje, ak nenpòt kondisyon espesifik oswa règleman nan rejyon ou an. Li enpòtan pou w konsilte espesifikasyon ak direktiv WEAG pou seleksyon ak enstalasyon apwopriye.

K: Èske EZ40 RCBO ka itilize kòm yon ranplasman pou yon disjoncteurs estanda?

A: Wi, EZ40 RCBO ka jeneralman dwe itilize kòm yon ranplasman dirèk pou yon disjoncteurs estanda, bay tou de pwoteksyon sikwi ak pwoteksyon aktyèl rezidyèl nan yon sèl aparèy. Sepandan, li enpòtan pou asire konpatibilite epi swiv enstriksyon WEAG la pandan enstalasyon an.

K: Ki diferans ki genyen ant EZ40 RCBO ak yon RCD/RCCB?

A: EZ40 RCBO konbine fonksyon yon disjoncteurs ak yon aparèy aktyèl rezidyèl (RCD/RCCB) nan yon sèl inite. Li bay tou de surcharge ak kout sikwi pwoteksyon (tankou yon disjoncteurs) ak pwoteksyon kont defo tè oswa kouran flit (tankou yon RCD / RCCB). Kontrèman, yon RCD/RCCB sèlman bay pwoteksyon kont defo tè oswa kouran flit.

K: Ki jan EZ40 RCBO detekte defo tè oswa kouran flit?

A: EZ40 RCBO detekte defo tè oswa kouran flit pa kontinyèlman kontwole koule aktyèl la nan tou de faz la ak kondiktè net. Si li detekte yon move balans ant de kouran yo, li byen vit vwayaje epi dekonekte kous la.

K: Ki diferans ki genyen ant EZ40 RCBO ak yon EA63s/EA63/EB63 MCB?

A: EZ40 RCBO bay tou de surcharge ak kout sikwi pwoteksyon, osi byen ke pwoteksyon kont defo tè oswa kouran flit. Kontrèman, EA63s/EA63/EB63 MCB (Miniature Circuit Breaker) sèlman bay surcharge ak pwoteksyon kout sikwi. EZ40 RCBO se esansyèlman yon MCB konbine avèk yon RCD/RCCB.

K: Èske EZ40 RCBO ka reset apre li vwayaje?

A: Wi, EZ40 RCBO yo gen yon fonksyon reset ki pèmèt yo manyèlman reset apre yo fin fè dezòd. Sepandan, li enpòtan pou envestige ak rezoud kòz vwayaj la anvan reset pou asire sekirite sistèm elektrik la.

K: Èske EZ40 RCBO yo sansib a ti kouran flit?

A: Wi, EZ40 RCBO yo fèt yo dwe sansib a ti kouran flit, tipikman nan seri a nan kèk miliampèr (mA). Sansiblite sa a asire ke menm ti defo tè oswa kouran flit yo detekte ak kous la byen vit dekonekte.

K: Èske EZ40 RCBO ka itilize nan tou de sistèm sèl-faz ak twa-faz?

A: Wi, EZ40 RCBO yo disponib pou itilize nan tou de sistèm elektrik sèl-faz ak twa-faz. Li enpòtan pou chwazi modèl ki apwopriye EZ40 RCBO ki baze sou kondisyon espesifik sistèm yo.

K: Èske plizyè EZ40 RCBO ka enstale nan yon tablo distribisyon sèl?

A: Wi, plizyè EZ40 RCBO ka enstale nan yon tablo distribisyon sèl pou pwoteje sikui diferan endividyèlman. Sa a pèmèt pou trinch selektif ak izolasyon nan sikui espesifik nan evènman an nan yon fay.

K: Èske EZ40 RCBO apwopriye pou enstalasyon deyò?

A: EZ40 RCBO yo fèt pou enstalasyon deyò epi yo gen evalyasyon espesifik oswa patiraj ki enpèmeyab ki bay pwoteksyon kont faktè anviwònman tankou imidite, pousyè, ak varyasyon tanperati.

 

Baj popilè: 10a 16a 20a 25a 32a 40a 2p 4p rcbo, Lachin 10a 16a 20a 25a 32a 40a 2p 4p rcbo manifaktirè, founisè

Voye rechèch
Voye rechèch